Pressure test methods for various valves(一)

Jun 13, 2023

Pressure test method for gate valve

The strength test gate valve is the same as the globe valve. There are two methods for the sealing test of gate valves.

Open the gate, increase the pressure inside the valve to the specified value; then close the gate, take out the gate valve immediately, check whether there is any leakage at the seals on both sides of the gate, or directly inject the test medium into the plug on the valve cover to specified value. Check the seal on both sides of the gate. The above method is called medium pressure test. This method is not suitable for the sealing test of gate valves with a nominal diameter of DN32mm or below.

Another method is to open the gate and increase the test pressure of the valve to the specified value; then close the gate and open the blind plate at one end to check whether there is leakage on the sealing surface. Reverse the magnetic head and repeat the above test until it is qualified. The sealing test of the pneumatic gate valve packing and gasket should be carried out before the gate sealing test.

Pressure test methods for globe valves and throttle valves 2

In the concrete strength test, the shut-off valve and the throttle valve, the assembled valve is usually placed on the pressure test stand, the valve disc is opened, the medium is injected into the specified value, and the valve body and valve cover are checked for sweating and leakage. Strength tests can also be performed on individual pieces. The air tightness test is only applicable to globe valves. During the test, the valve stem of the stop valve is in a vertical state, the valve disc is opened, and the medium is introduced from the bottom of the valve disc to the specified value. Check the packing and gasket; after passing the test, close the disc and open the other end to check for leakage.

If the strength and tightness test of the valve is carried out at the same time, the strength test can be carried out first, and then the pressure is reduced to the specified value of the tightness test, and the packing and gasket are checked; then the valve disc is closed, the outlet port is opened, and the sealing surface is checked for leakage.