Test methods for ductile iron pipe fittings

May 13, 2022

1. The tensile test of plain tensile strength shall be carried out according to the provisions in GB 228.

2. The surface and coating quality of ductile iron pipe fittings are inspected by visual inspection.

3. The air tightness test of ductile iron pipe fittings should be carried out before coating. When the pressure reaches the specified value, the voltage stabilization time should not be less than 10s, and the water will not leak at this time.

4. The size of ductile iron pipe fittings can be measured with calipers and other measuring tools.

5. The water pressure test should be carried out before coating. When the pressure reaches the specified value, the voltage stabilization time should not be less than 10s, and no leakage should occur at this time.

6. The hardness test of ductile iron pipe shall be carried out according to the regulations in GB231.


Send Inquiry